Share:


FLIR A400/A700 Professional Science Kit

Quantity: In Stock



FLIR A400/A700 Professional Science Kit

FLIR A400 and A700 Science Kits offer researchers and engineers a streamlined solution for accurate temperature measurement. Simplified yet robust connections help you set up and start testing quickly; then easily view, acquire, and analyze data using included FLIR Research Studio software. The Standard kit includes a FLIR A400 or A700 Image Streaming camera, 24° lens with automatic/remote and manual focusing, as well as FLIR Macro Mode. The Professional kit has the added benefits of MSX® image enhancement, radiometric data transmission over Wi-Fi, and a close-up lens for accurate thermal measurements on small components.

product image
SPECIFICATIONS
IR Resolution
320 × 240
Detector Pitch
17 µm
Pixel Pitch
17 µm
Spectral Range
7.5–14.0 µm
Detector Type
Uncooled microbolometer
Dynamic Range
16-bit
Thermal Sensitivity/NETD
Lens dependent: <30 mK to <50 mK
Frame Rate
30 Hz
Standard Temperature Range
-20°C to 120°C (-4°F to 248°F); 0°C to 650°C (32°F to 1202°F); 300°C to 1500°C (572°F to 2732°F)
Focus
One-shot contrast, motorized, manual
IMAGING & OPTICAL
Available Lenses
6°, 14°, 42°
Detector Pitch
17 µm
Detector Type
Uncooled microbolometer
Digital Data Streaming to PC
Gigabit Ethernet (RTSP, GigE Vision) or Wi-Fi stream to workstation running included Research Studio Software
Dynamic Range
16-bit
Field of view (FOV)
24° × 18°
Focus
One-shot contrast, motorized, manual
Frame Rate
30 Hz
Image Modes
MSX®, Picture-in-picture, blending, and fusion
IR Resolution
320 × 240
Lens
24°, 2.0x Macro
Lens Identification
Automatic
Macro Mode
Included
Minimum Focus Distance
2.0x Macro: 18 mm (0.71 in) 24°: 0.15 m (0.49 ft) 24° with Macro Mode: 17 mm (0.67 in) 42°: 0.15 m (0.49 ft) 14°: 1.0 m (3.28 ft) 6°: 5.0 m (16.4 ft)
Pixel Pitch
17 µm
Spectral Range
7.5–14.0 µm
Thermal Sensitivity/NETD
Lens dependent: <30 mK to <50 mK
Visible Camera
1280x960
MEASUREMENT & ANALYSIS
Accuracy
±2°C (±3.6°F) or ±2% of reading for ambient temperature 15°C to 35°C (59°F to 95°F), object temperature above 0°C (32°F)
Standard Temperature Range
-20°C to 120°C (-4°F to 248°F); 0°C to 650°C (32°F to 1202°F); 300°C to 1500°C (572°F to 2732°F)
COMMUNICATION & DATA STORAGE
Command and Control
Gigabit Ethernet (RTSP, GigE Vision), Wi-Fi
Digital I/O connector type
M12 Male 12-pin A-coded (shared with ext. power)
Digital Inputs
2× opto-isolated, Vin (low) = 0–1.5 V, Vin (high) = 3–25V
Digital Outputs
3× opto-isolated, 0–48 VDC, max. 350 mA (derated to 200 mA at 60°C). Solid-state opto relay, 1× dedicated as fault output (NC)
Ethernet Communication
GigE Vision ver. 1.2, Client API GenICam compliant, TCP/IP socket-based (FLIR proprietary)
Ethernet Connector Type
M12 8-pin X-coded, female
Ethernet Image Streaming
Yes
Ethernet Power
Power over Ethernet, PoE IEEE 802.3af class 3
WiFi
Connector: Female RP-SMA Standard: IEEE802.11a/b/g/n Connections: Peer to peer (ad hoc) or infrastructure (network)
GENERAL
Size [L x W x H ] w Lens
123 × 77 × 77 mm (4.84 × 3.03 × 3.03 in)
POWER
External Voltage
18-56 VDC, 8 W max
Power
24/48 V DC 8 W max
Power Cable Configuration
Power over Ethernet or External
Power Connection
M12 Male 12-pin A-coded (shared with Digital I/O)
ENVIRONMENTAL & CERTIFICATIONS
Encapsulation
IEC 60529, IP 54, IP66 with accessory
Mounting
UNC ¼″-20 on 2 sides 4× M4 on 4 sides
Operating Temperature
-20°C to 50°C (-4°F to 122°F): • -20°C to 40°C (-4°f to 104°F) (in free air) • 40°C to 50°C (104°F to 122°F) (mounted on cooling plate accessory) • Maximum camera case temperature: 65°C (149°F)
Shock
IEC 60068-2-27, 25 g
Storage Temperature Range
IEC 68-2-1 and IEC 68-2-2, -40°C to 70°C (-40°F to 158°F) for 16 hours
Vibration
IEC 60068-2-6, 0.15 mm at 10–58 Hz and 2 g at 58–500 Hz, sinusoidal IEC 61373 Cat 1 (Railway)


 Inquiry - FLIR A400/A700 Professional Science Kit